G31 P90 captures a coordinate without stopping the axis. Check axis count for PS5068 and the P word for PS0369.

Contents
  1. Purpose and model coverage
  2. Position capture does not stop the axis
  3. Separate block format from an unavailable function
  4. Authorization and machine checks
  5. References

Purpose and model coverage

Continuous High-Speed Skip captures absolute positions at several points along a single-axis move for use by Custom Macro. The FANUC Plus catalog lists A02B-0349-J770 for the 0i-TF Plus and A02B-0350-J770 for the 0i-MF Plus. The connection manual requires continuous high-speed skip, high-speed skip and Custom Macro. This article follows the cited 0i-F Plus manuals; confirm the minimum CNC software release with the authorized provider.

Position capture does not stop the axis

A G31 P90 block specifies one travel axis and is nonmodal. Unlike ordinary G31, a valid signal captures a position without ending the move: the axis continues to the programmed endpoint. For example, two marker pulses from a measuring system can capture two positions during an uninterrupted pass. The macro variables give access to a captured position; do not assume they automatically keep a history of all events. Never use this command to stop on contact or as a collision safeguard. The next valid event updates the macro variables. To keep multiple points, read and save each value before the next event.

Separate block format from an unavailable function

PS5068 (FORMAT ERROR IN G31P90) means no travel axis was specified, or two or more were specified. Review the alarm block offline and count the axis addresses. With PS0369 (G31 FORMAT ERROR), identify the P word first. For P90, the manual lists continuous high-speed skip not being effective; for P98/P99, an invalid axis count or a Q outside 1–254 can raise the same alarm. PS0369 alone does not prove J770 entitlement is missing.

Authorization and machine checks

Give FANUC or the machine builder the serial number, CNC model, software series and revision, and installed option list. Check the order code, prerequisite functions and machine wiring. If there is no alarm but coordinates are not captured as expected, verify the selected high-speed input and active edge against the OEM documentation without forcing signals or changing parameters. Commission through the authorized provider; never test whether a live probe will stop the axis on contact.