FANUC 21i-MB J957: COPY, MERGE and the O0000 work program
Where does COPY put a selection if you leave the program number blank? How to keep it, and why clearing alarm 101 can cost you an edited program.
Contents
Extended part program editing on the 21i-MB is more than changing individual words. COPY puts the selected text into another program. MERGE inserts an existing program into the one you have open. The distinction matters when you need the source to survive a second edit.
What J957 identifies
FANUC Descriptions B-63522EN/02, p. 20 lists basic, background and extended editing separately and marks extended editing optional on both the 21i-MB and 21i-TB. Item 17 on sheet YT48359, page 4/4, of the 21i-MB build record identifies extended editing as 0286-J957. The full order number is A02B-0286-J957; the model prefix is corroborated by the FANUC B-63734EN/01 preface. This is the documented MB order number, not a TB order number or proof that any particular machine has the option.
COPY picks a program number; MERGE picks a position
Suppose you want a note from an older program to appear just before the unclamping reminder in a revised one. Back up both programs. In EDIT, select the start and end of the note and use COPY to save it under a confirmed unused number, say O4321. Open the destination, place the cursor at the beginning of the unclamping reminder, and use MERGE with O4321 as the source. The text goes before the selected cursor position, and O4321 stays unchanged. This example shows text placement, not a runnable program.
See the 21i-MB Operator’s Manual B-63614EN/01, pp. 605 and 607. The 21i-TB Operator’s Manual B-63604EN/01, pp. 574 and 576–578, documents the same editing behavior, not the MB order number.
O0000 is a work program, not a backup
On MB manual p. 608, if you execute COPY or MOVE after setting the range but leave the program number blank, the control stores the selection as work program O0000. Another COPY or MOVE without a program number replaces it; MERGE does not clear it. FANUC explicitly says not to run this work program. To keep the selection, use a verified unused normal program number and keep a separate backup.
Alarm 70 and alarm 101 are different failures
On MB manual p. 609, alarm 70 means the control ran out of memory during copying or insertion and stopped the operation. Check free capacity and the current destination before retrying. Alarm 101 concerns power interrupted during copy, move or insertion. The documented clearing procedure deletes the program being edited at the time. Record the exact alarm and identify the affected program and a usable backup before an authorized technician follows the applicable procedure. Neither alarm establishes that J957 is absent.
If the soft keys are missing, verify the exact CNC model, the screen open in EDIT and the soft-key menu page. Check the build record or have the machine builder or FANUC service confirm the option rather than changing parameters to see what happens.
Neither a minimum CNC software revision nor a dedicated missing-option alarm was verified.
If alarm 70 keeps returning, see how program capacity differs from the number of registered programs and editing options before deciding what to check.