MS2508 means compensation cannot continue. MS2509 means it is running without sensors, not that the sensors have recovered.

Contents
  1. Standard compensation and the sensor option
  2. The sensor option is not a field software upgrade
  3. What the three messages say is happening
  4. Capture the state before resuming production

A ROBODRILL shows MS2508 before shutdown and MS2509 after restart. The newer message can look like a recovery. On the α-DiB5 with the non-Plus 31i-B5, what changed was the compensation state, not the condition of the sensors.

Standard compensation and the sensor option

The FANUC Operator’s Manual B-85444EN-1/03, §§15.1–15.2.2, pp. 295–297, says standard compensation estimates X, Y and Z thermal displacement caused by machine motion without temperature sensors. The compensation graph is not a measurement of actual displacement and may still display values for times when compensation was off. A visible trace does not prove compensation was applied.

The sensor option is not a field software upgrade

The same manual, §§15.4.1–15.4.2, p. 319, says the option uses measured temperature for compensation and cannot be added after purchase on this series. Turning on a fitted feature from the operator screen does not give a machine without the sensors that capability. Verify the factory build by machine serial number. The manual also warns that nonstandard lubrication equipment or lubricant can affect accuracy.

What the three messages say is happening

MS2507: a temperature sensor fault was detected. FANUC says compensation can continue with reduced precision if only one sensor is abnormal. MS2508: too many sensors are abnormal for compensation to continue. MS2509: compensation is being performed without sensors. The manual describes this fallback to standard compensation after the next power-on when excessive sensor faults prevented compensation. MS2509 is not confirmation that the sensors are fixed or the dimensions are back in tolerance.

Capture the state before resuming production

Save the full message, when it appeared (cold, during production or after restart), and the sensor check window status. Have service personnel identify and replace the affected components per the manual. Distinguish MS2506, a reference-temperature message, and MS2510, a suspected sensor fault, from MS2508. For tolerance-sensitive parts, follow the established inspection procedure before resuming work; do not rely on a restart or compensation adjustment as a repair.

Related: 0i-F diagnostics 308/309 for motor and encoder temperature (Chinese). That is an overheat diagnostic on a different series, not the ROBODRILL compensation sensor check.