Independent CNC repair and technical reference Contact

FANUC 0i-D R670: how DS5351, DS5350 and DS5340 differ

Published Updated

DS5351 points to the monitoring function itself; DS5350 concerns registered parameter verification; DS5340 is a parameter checksum mismatch.

Contents
  1. R670 checks registered settings
  2. The three numbers are not interchangeable
  3. Manual editions do not date the firmware
  4. Preserve the baseline and maintenance record

DS5351 points to the monitoring function itself; DS5350 concerns registered parameter verification; DS5340 is a parameter checksum mismatch.

R670 checks registered settings

FANUC’s 2013 catalogue, printed p. 462 (PDF p. 463), describes verification at CNC power-up of registered items such as selected CNC parameters. A detected change can produce a signal and can be configured to raise an alarm. The ordering codes are A02B-0319-R670 for 0i-TD, A02B-0320-R670 for 0i-MD, A02B-0321-R670 for 0i Mate-TD and A02B-0322-R670 for 0i Mate-MD. Catalogue availability does not establish installation on a particular machine. FANUC Function Catalogue, p. 462.

The three numbers are not interchangeable

In B-64305CM/05 Appendix A.1, printed p. 431, DS5351 means the setting modification warning function is not operating normally, but the entry does not identify the precise trigger. DS5350 means the CNC parameters differ from those present when the check code was registered. DS5340 means a parameter change produced a checksum different from the reference checksum. Timing after maintenance does not identify the changed parameter or person, or establish that pitch error compensation was involved. Chinese maintenance manual B-64305CM/05, p. 431.

Manual editions do not date the firmware

The matching DS section of B-64305EN/03 runs through DS5340 on printed p. 472 (PDF p. 490), then moves to IE alarms on the next page. B-64305CM/05 also lists DS5350 and DS5351 in its corresponding section. This shows a difference in documentation coverage, not when DS5351 first appeared in CNC software. No minimum software revision or alarm specifically indicating absent R670 was verified. Do not apply procedures from other controller families. English maintenance manual B-64305EN/03, pp. 472–473.

Preserve the baseline and maintenance record

Capture the complete alarm and time, alarm history, CNC model and software series/revision, the registered baseline record, last known-good backup and authorized maintenance log. Compare available records in offline copies; leave unexplained differences for the machine builder to verify. Ask FANUC or the builder to confirm actual entitlement and applicable manuals against the serial number. Do not re-register the baseline, edit parameters, restore a backup or try passwords to clear the alarm; none of those steps verifies its cause.