Check licensing, mode switching and reference establishment separately. PS0303 is not proof that J852 is absent.
Contents
Do not infer licensing from an alarm
A spindle that rotates but alarms during angular positioning gives you a starting point, not an option diagnosis. Record the full alarm, failing block and preceding mode transition. Preserve a parameter backup rather than changing bits repeatedly to make the message disappear.
What J852 provides
The 2024 FANUC catalogue, page 43, lists A02B-0327-J852 for 31i-B. Cs contour control provides spindle position control and interpolation with feed axes, using the appropriate spindle detector.[1]
Confirm the transition actually finished
B-64483EN-2/01 distinguishes speed control from Cs position control and a mode request from completion status; PMC signals perform the switching.[2] Use the builder’s procedure and axis names, not a generic M code found online. Record “requested” and “completed” separately. Reaching a program line is not evidence of a completed transition.
PS0303 has a specific documented condition
B-64490EN/05, page 202: with arbitrary-position reference setting CRF enabled, commanding G00 after entering Cs without first returning to reference causes PS0303 (REFERENCE POSITION RETURN IS NOT PERFORMED), even with NRF at 0.[3] This describes an alarm condition, not an instruction to change CRF or NRF.
Missing option and authorized addition
The reviewed evidence does not establish one alarm that always means J852 is missing, so no such lookup table is offered. PS0303 does not establish authorization either. Check formal option records and the reference procedure independently. Ask FANUC or the builder to confirm compatibility, authorized addition and acceptance requirements from the serial number, full CNC model, software revision and spindle/detector configuration. Parameter configuration is not a license.
Prepare a useful service record
Use four columns: installed-function record, before/after switching state, first axis-motion command and full alarm text. If the first G00 after switching fails, have service personnel check the machine’s reference procedure; do not substitute another motion type to evade the alarm. No runnable program is supplied. Qualified personnel must validate movement under the builder’s safety procedure. Scope is 31i-B and the cited documents; /01 and /05 are manual editions, not software versions. The minimum software revision is unverified; Plus is not covered and no machine test is claimed.