FANUC 31i-B S853: why adding axes can invalidate a working involute program
S853, J655 and the total simultaneous-axis limit are separate checks. Diagnose PS0021 after adding axes without treating it as proof of a missing option.
Contents
A working curve is not an axis-capacity test
A successful two-axis involute program does not establish that its extended spatial path is executable. The key is to check the added-axis combination against system capability. Preserve both program versions and compare the axis addresses that actually changed, not just the G codes.
What S853 adds
The FANUC catalogue lists A02B-0327-S853 for 31i-B: S853 alone permits two involute axes plus up to two other linearly interpolated axes. Three or four additional axes require J655 as well as sufficient total simultaneous-axis capacity. “Additional” excludes the two curve-plane axes.[1]
Check the axis combination
B-64484EN-2/03 §3.1.2 uses G02.2/G03.2 with other-axis addresses added to the selected-plane involute command; those addresses must not be the plane axes.[2] An audit sheet can separate curve-plane axes from additional axes, then total the axes moving in the block. This classification is not an executable program or a promise that every six-axis machine qualifies.
PS0021 does not prove S853 is absent
B-64485EN/01 gives PS0021 as ILLEGAL PLANE SELECT, covering plane/axis errors and missing required helical interpolation; PS0015 concerns excessive simultaneous axes.[3] The reviewed evidence does not uniquely map an alarm to absent S853. After PS0021, compare plane selection and axis definitions before checking installed functions. After PS0015, check actual simultaneous-axis capacity separately. Do not simply delete axis commands to clear an alarm: splitting motion may change the part path.
Authorized addition and acceptance
Scope is 31i-B with these manuals. /03 and /01 identify document editions, not software revisions; the minimum software revision was not verified, and Plus is not covered. Give FANUC or the builder the full model, serial number, software revision, option record and required axis combination. Request confirmation of S853, J655 and simultaneous-axis capability and use their authorized addition process. No machine-specific installation steps were confirmed here; parameter changes are not licensing. Check hardware, axis configuration and authorization separately. Back up first and have qualified personnel follow builder safety and acceptance procedures. No machine test is claimed.
Make the change visible to service staff
Keep the alarm number, failing block, plane mode and option-check results for both versions in one record. This reveals what changed without using a trial run as evidence of the entire machine’s licensing. Review geometry and collision risks offline before controlled acceptance.